Siemens SIMATIC NET SCALANCE S615 Configuration Manual page 142

Industrial ethernet security web based management
Hide thumbs Also See for SIMATIC NET SCALANCE S615:
Table of Contents

Advertisement

Configuring with Web Based Management
4.7 "Layer 3" menu
● "Translated Source IP Address" input box
Enter the IP address with which the IP address of the sender is replaced. Can only be
edited if "Use Interface IP from Destination Interface" is disabled.
● "Destination IP Address(es)" input box
Specify the destination IP addresses for which this destination NAT rule is valid. Only the
packets whose destination IP address is in the range of entered addresses are taken into
account.
– IP address: Applies precisely to the specified IP address.
– 0.0.0.0/0: Applies to all IP addresses
– IP address range: Applies to the specified IP address range: Start IP address "-" End
– IP address band: Applies to the IP addresses covered in the IP address band: IP
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Source Interface
Shows the source interface.
● Destination Interface
Shows the destination interface.
● Source IP Address(es)
Shows the IP addresses of the senders for which address translation is required.
● Translated Source IP Address
Shows the IP address with which the IP address of the sender is replaced.
● Destination IP Address(es)
Shows the IP addresses of the recipients for which address translation is required.
142
IP address, e.g. 192.168.100.10 - 192.168.100.20
address/number of bits of the network part (CIDR notation)
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02