Unit still does not communicate

A situation may occur which causes the unit to completely not function. Here are possible
problems
:
Terminal Server User Guide
Unit still does not communicate
Problem
Port locked
Power cycling
Network errors
Network cable problems
Configuration problems
Power problems
Hardware problems
Action required
Try killing the port as it may be locked due to some
situation that is no longer obvious. Also, killing the port
ensures that any changes in the configuration will be
acted upon.
Power cycle the device connected (if this is possible) as
it may be that it has locked, or the set-up within the
device is in error. Also try power cycling the unit itself.
Try 'pinging' the unit to establish connection.
Check the network cable again. Does it work on another
node correctly. Is the BNC (or AUI) connector fitted
correctly?
Check the IP address again on the Server Menu.
Is the green LED power light on? Check the power itself
with the plug, wall socket, fuses, etc. Is the green LED
power light dim? Call your supplier or technical support.
If all three network LEDs are flashing continuously on/off
at approx 4Hz. this may point to a memory fail test.
Call your supplier or technical support.