Setting Trace Modes - Renesas M16C/64 User Manual

Emulator mcu unit for m16c/64 group
Table of Contents

Advertisement

R0E530640MCU00 User's Manual
5.9.4

Setting Trace Modes

(1) Setting trace modes
Following five trace modes are available.
Table 5.14 Trace modes
Stop mode
1
Fill until stop
2
Fill until full
3
Fill around TP
4
Repeat fill until stop
5
Repeat fill until full
CAUTION
Recording is made in units of total 512 cycles, consisting of 1 cycle at the line where a trace point is met and 255 cycles before
that point and 256 cycles after that point.
Figure 5.49 Differences between the trace modes
Specifiable conditions vary depending on trace mode, as summarized in the table below.
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 124 of 229
Description
Trace acquisition continues until the program stops running.
Trace acquisition stops when the trace memory is filled.
Trace acquisition stops a specified number of cycles after a
trace point is encountered. A delay value can be specified in
a range of up to the maximum value of trace capacity.
Each time a trace point is encountered, acquisition is made
for a total of 512 cycles* before and after that point, and
acquisition continues that way until the program stops
running.
Each time a trace point is encountered, acquisition is made
*
for a total of 512 cycles
before and after that point, and
acquisition continues that way until the trace memory is
filled.
5. Debugging Functions