Self-Check - Renesas M16C/64 User Manual

Emulator mcu unit for m16c/64 group
Table of Contents

Advertisement

R0E530640MCU00 User's Manual

2.7 Self-check

The self-check is to check the emulator functions operate properly. To run the self-check function of the emulator, follow the
procedure below. While the self-check is in progress, the LEDs will change as shown in Figure 2.6. In case of ERROR,
because the target status LEDs will change depending on errors, check the system status LEDs.
(1) If the user system is connected, disconnect the converter board and the user system.
(2) Turn on the emulator.
(3) Launch the emulator debugger, and select the Start booting up on successful completion of self checking check box in the
Device Setting dialog box.
(4) When you click OK, the self-check will start. If the normal result is displayed in about 60 seconds, the self-check ends
normally.
Emulator turned on
: ON
: OFF
: Flashing
: ON or OFF
: Indefinite
Figure 2.6 LED displays during the self-check
REJ10J1733-0100 Rev.1.00 Apr. 01, 2008
Page 29 of 229
Self-check started
or
Self-check executed
Self-check
terminated normarlly
Self-check error
Note:
See the error display of the debugger