Jumper Setting - Renesas MCI-HV-1 User Manual

Table of Contents

Advertisement

MCI-HV-1 User's Manual

2.4 Jumper setting

Default setting and function of the jumpers (JP1~JP16) are as follows.
Jumper pin
JP1, JP2
JP3
JP4
JP5, JP6, JP7
JP8, JP9, JP10,
JP11, JP12, JP13
JP14
JP15, JP16
R12UZ0138EJ0100 Rev.1.00
February 28, 2024
Table 2-4 Jumper setting of inverter board
Default setting
1-2pin short: 3-shunt current sensing
1-2pin short
2-3pin short: 1-shunt current sensing
1-2pin short: select IPM temperature signal
2-3pin short
2-3pin short: select PFC phase current signal (ch2)
1-2pin short: SW1 level HIGH
2-3pin short
2-3pin short: SW1 level LOW
1-2pin short: HALL signal input
2-3pin short
2-3pin short: Encoder signal input
1-2pin short: use PGA on CPU board for current sensing
2-3pin short
2-3pin short: use Amp on inverter board for current sensing
Changing settings is prohibited.
open
1-2pin short: 1-shunt current sensing for PFC
1-2pin short
2-3pin short: 2-shunt current sensing for PFC
Fig. 2-3 Default jumper pin setting of inverter board
Function
Page 8 of 24