MFD & PFD MESSAGE ADVISORIES (CONT.)
Message
PFD1 CONFIG – PFD1 config error.
Config service req'd.
PFD2 CONFIG – PFD2 config error.
Config service req'd.
MFD1 CONFIG – MFD1 config error.
Config service req'd.
SW MISMATCH – GDU software
version mismatch. Xtalk is off.
PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.
PFD2 COOLING – PFD2 has poor
cooling. Reducing power usage.
MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK – PFD1 [key name] Key
is stuck.
PFD2 KEYSTK – PFD2 [key name] Key
is stuck.
MFD1 KEYSTK – MFD [key name] Key
is stuck.
CNFG MODULE – PFD1 configuration
module is inoperative.
PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage
PFD2 VOLTAGE – PFD2 has low
voltage. Reducing power usage
MFD1 VOLTAGE – MFD1 has low
voltage. Reducing power usage
DATABASE MESSAGE ADVISORIES
Message
MFD1 DB ERR – MFD1 navigation
database error exists.
PFD1 DB ERR – PFD1 navigation
database error exists.
PFD2 DB ERR – PFD2 navigation
database error exists.
658
Comments
The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
The MFD and PFDs have different software versions installed. The G1000 system
should be serviced.
The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.
A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by pressing
it several times. The G1000 system should be serviced if the problem persists.
The PFD1 configuration module backup memory has failed. The G1000 system should
be serviced.
The PFD1 voltage is low. The G1000 system should be serviced.
The PFD2 voltage is low. The G1000 system should be serviced.
The MFD voltage is low. The G1000 system should be serviced.
Comments
The MFD and/or PFD detected a failure in the navigation database. Attempt to reload
the navigation database. If problem persists, the G1000 system should be serviced.