Symbol Data Output
Good Read
Usage:
Good Read is used when an application requires all symbol data to be
transmitted. It's typically used in tracking applications in which each
object is uniquely identified.
Definition:
With
Good Read
good read regardless of Matchcode Type setting.
Note: A noread can still be transmitted if enabled.
When to Output Symbol Data
Definition:
This command allows the user to choose when symbol data can be sent
to the host.
Serial Cmd:
<Klsymbol data output
Default:
As Soon As Possible
Options:
0 = As Soon As Possible
As Soon As Possible
Usage:
As Soon As Possible is useful in applications in which symbol data
needs to be moved quickly to the host, typically when the host is making
decisions based on symbol data.
Definition:
Enabling
As Soon As Possible
immediately after a symbol has been successfully decoded.
Note: More than one decode might in fact be required to qualify as a
good decode, depending on how Decodes Before Output is set.
MS-710 Scanner User's Manual
6-4
enabled, the scanner transmits symbol data on any
mode,when to
output>
1 = End of Read Cycle
causes symbol data to be sent to the host