Transition Counter
Usage:
Can be useful in certain application where extraneous objects in the field
of view might require a higher threshold.
Definition:
Determines the number of bar/space transitions that are sampled before
AGC can be resolved.
Serial Cmd:
<KHsymbol detect
Default:
14
Options:
3 to 255
Reflectance Threshold
Note: Reflectance Threshold applies only to those MS-710 models that include an
MS-Sensor. See
"MS-Sensor" on page
Definition:
The number is derived by testing the reflectivity of empty space.
Usage:
Allows you to set the reflectance threshold—the level at which an object
is detected.
Serial Cmd:
<KHsymbol detect status,transition
Default:
40
Options:
0 to 255
To setup the MS-Sensor, select a number that is one or two numbers greater than the
value posted when nothing is in the scanner's beam. See
1
24.
Scanner Type
Usage:
This field is
READ
tory setup.
Definition:
This field displays the current factory-set scanner density type.
Serial Cmd:
<KPdensity>
Default:
The default depends on the type of scanner that was ordered.
Options:
0 = Standard
1. Reflectance can also be modified by sending the <KQoffset> test command which samples 50
scans for the highest reflectance value and adds a user-defined offset to this value.
MS-710 Scanner User's Manual
Chapter 4 Read Cycle
status,transition
counter,reflectance threshold>
A-24.
counter,reflectance
"MS-Sensor" on page A-
ONLY, and is set by a qualified technician during fac-
1 = High Density
threshold>
4-17