Polycom SpectraLink 6000 Maintenance And Diagnostics page 50

Hide thumbs Also See for SpectraLink 6000:
Table of Contents

Advertisement

SpectraLink 6300 MCU: Maintenance and Diagnostics: SpectraLink 6000 System
Component -
Alarm -
Second LED
First LED
RCU 1 - 6
Disabled - 1, 3, 4
RCU 1 - 6
Download - 1, 2, 4
RCU 1 - 6
Errors - 2, 3, 4
RCU 1 - 6
Lockout - 1, 3, 5
RCU 1 - 6
Type - 1, 4
50
Probable Cause
Base Station (RCU) not
configured but present, or
Base Station (RCU) disabled.
Base Station (RCU) download
failed.
Base Station (RCU)/MCU link
errors too high.
Base Station (RCU) locked out
following startup listen.
Unsupported Base Station
(RCU) type (not Base Station
3.0).
Recommendation
Check if Base Station is
configured. If not, configure
through the Operator's Console.
If Base Station is disabled, see
Base Station Disabled in
Chapter 4 Base Station
Problems.
Reset Base Station. See Base
Station Will Not Download in
Chapter 4 Base Station
Problems. If problem persists,
contact Polycom Customer
Support.
Check cabling, if OK replace
Base Station.
Reset Base Station. If problem
persists, contact Polycom
Customer Support.
Replace Base Station with
supported Base Station type.
Notes
PN: 1725-36123-001_K.doc

Advertisement

Table of Contents
loading

Table of Contents