SpectraLink 6300 MCU: Maintenance and Diagnostics: SpectraLink 6000 System
Component -
Alarm -
Second LED
First LED
Router- 1
Keepalive –
2, 3, 4
Router -1
No code - 2, 4
Sys Config -
No code - 2, 4
2, 3
UART1 - 4
Read - 1, 2, 5
UART2 - 1, 3
UART1 - 4
RX full - 5
UART2 - 1, 3
UART1 - 4
TX full - 1, 5
UART2 - 1, 3
UART2 - 1, 3
HW - 2, 3, 5
42
Probable Cause
Internal error.
Bad SW download.
Bad SW download.
Bad serial port
communications.
Internal error.
Internal error.
System Controller does not
support Open Applications
Interface (OAI) but has been
configured for OAI.
Recommendation
Contact Polycom Customer Support.
Check supervisor software. If you just
did a download, retry the download. If
a no download was done lately, the
board is probably bad.
Check supervisor software. If you just
did a download, retry the download. If
a no download was done lately, the
board is probably bad.
Verify serial port works properly on
the Operator's Console PC.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Unconfigure the OAI support on the
System Controller.
Notes
IPC Communications will not work
in system. Keepalive card alarms
can be seen because of conditions
causing this alarm.
IPC Communications will not work
in system. Keepalive card alarms
can be seen because of conditions
causing this alarm.
IPC Communications will not work
in system. Keepalive card alarms
can be seen because of conditions
causing this alarm.
PN: 1725-36123-001_K.doc
Need help?
Do you have a question about the SpectraLink 6000 and is the answer not in the manual?