SpectraLink 6300 MCU: Maintenance and Diagnostics: SpectraLink 6000 System

Boot ROM Alarms

LED 1
LED 2
1
1
1
2
1
1, 2
1
3
1
1, 3
1
2, 3
1
1, 2, 3
1
4
1
1, 4
2
1
2
2
2
1, 2
2
3
1, 2
1
1, 2
2

Downloads

30
During system boot, if alarms are encountered the red LED will be on.
The alarm code will display on the green status LEDs, consisting of
one second of blank lights followed by two LED sequences which
each display for one second.
Description
RAM test failed.
Flash type incorrect.
Boot code CRC incorrect.
Factory page CRC incorrect.
Downloader CRC incorrect.
Bad board type.
Bad board slot.
Bad functional code.
Incompatible functional code
version.
Error starting IPC.
Supervisor communications
refusal.
No keepalives detected.
Bad shelf number.
Error writing or erasing flash.
Error downloading FPGA (not
used by Interface Module).
During downloads, either from the serial port or across the IPC, the
green LEDs 'count' up to show progress in the download. Each serial
packet or IPC page increments the count and it wraps to zero after
getting to 31.
Recommendation
Replace card.
Replace card.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
Card requires newer version of functional
code. Contact Polycom Customer Support.
Replace card.
Interface Module card is not configured for
PBX type.
Shelf Controller card is not yet operating.
Contact Polycom Customer Support.
Replace card.
Replace card.
PN: 1725-36123-001_K.doc