Before adding a new Base Station you should have a port location for
the new equipment. If no ports are available on the SpectraLink 6300
MCU, you must install another Interface Module in the shelf. See
SpectraLink 6300 MCU: Installation.
1. Install the new Base Station. See SpectraLink 6300 MCU:
Installation.
2. On the Operator's Console, press F4,
.
and Administration
3. Using the arrow keys or mouse, position the cursor on the port
location to be configured, and press Enter.
4. When the menu displays, scroll down to
and press Enter.
5. At the pop-up menu, type the information for each Base Station.
Offset IDs manage the division of the frequency (spectrum)
Offset
among the Base Stations. To prevent interference, neighboring
Base Stations require different offset values. Each Base Station is
assigned a unique two-digit offset. Press the right arrow key to see
a menu of choices.
For half-hop systems with up to 25 Base Stations, or whole-
hop systems with up to 50 Base Stations, number the Base
Stations in order 1 through 25 or 1 through 50.
If the system has more Base Stations, the offset IDs must be
reused. Consult the map that was generated during system
installation. Assign unique offsets such that adjacent or nearby
Base Stations do not share the same offset. When selecting
offset assignments, keep in mind through-floor penetration
and the Base Station's proximity to windows.
Offset usage is summarized on the
function from F2 -
many times each Offset has been used.
If this Base Station is isolated from all other Base Stations,
Isolated?
enter
. An isolated Base Station is one that is located physically
Y
apart from other Base Stations, therefore will never be heard
during a Listen Verify diagnostic. Designating a Base Station as
Portcard Configuration Display