Polycom SpectraLink 6000 Maintenance And Diagnostics page 40

Hide thumbs Also See for SpectraLink 6000:
Table of Contents

Advertisement

SpectraLink 6300 MCU: Maintenance and Diagnostics: SpectraLink 6000 System
Component -
Alarm -
Second LED
First LED
Funnel - 2
Program - 3, 4
Funnel - 2
Start - 1, 3, 4
Funnel -2
No code - 2, 4
IPC - 3
Error - 1, 2, 3,
4
IPC – 3
RX full - 5
IPC - 3
TX full - 1, 5
IPC- 3
Start - 1, 3, 4
IPC - 3
HW - 2, 3, 5
MCU - 1, 2, 4
Error - 1, 2, 3,
4
40
Probable Cause
Funnel/router FPGA on System
Controller will not accept a
download.
Internal error.
No valid code to program
Funnel FPGA.
IPC communications can be
temporarily disturbed when a
card is hot inserted or a shelf is
powered on.
Supervisor encountered a
temporary period of heavy
traffic.
Supervisor encountered a
temporary period of heavy
traffic.
HW failed to start in the System
Controller card.
Cabling problem between the
Shelf Controller and the System
Controller.
Internal error.
Recommendation
Replace System Controller card.
Contact Polycom Customer Support.
Check supervisor software. If you just
did a download, retry the download. If
a no download was done lately, the
board is probably bad.
If problem persists, contact Polycom
Customer Support.
Contact Polycom Customer Support.
Contact Polycom Customer Support.
If the result of a software download to
system, check downloaded code.
Replace System Controller card.
Check cabling. If problem persists,
contact Polycom Customer Support.
Contact Polycom Customer Support.
Notes
IPC Communications will not work
in system. Keepalive card alarms
can be seen because of conditions
causing this alarm.
As a result of this error, audio may
be interrupted on calls where the
Base Station and the line are on a
different half-shelf.
IPC Communications will not work
in system. Keepalive card alarms
can be seen because of conditions
causing this alarm.
Alarm can occur in conjunction
with Control Switch alarms.
PN: 1725-36123-001_K.doc

Advertisement

Table of Contents
loading

Table of Contents