If the DHCP server is available, you can click the DHCP checkbox to automatically
obtain an IP address and other network settings from that server.
Two self-adaptive 10M/100M/1000M network interfaces provided for
non-POE series and two working modes are configurable: multi-address,
network fault tolerance, etc. One self-adaptive 10M/100M/1000M
network interface is provided for others.
NOTE
For the POE series NVR, you need to configure the internal NIC address,
so that IP addresses are assigned to the cameras that are connected to the
PoE interfaces.
After you configure the general settings, click Apply to save the settings.

Figure 11-2 Net Fault-tolerance Working Mode

Working Mode: Two 10M/100M/1000M NIC cards are provided and it allows the
device to work in the Multi-address and Net-fault Tolerance modes.
Multi-address Mode: The parameters of the two NIC cards can be configured
independently. You can select LAN1 or LAN2 in the NIC type field for parameter
settings. You can select one NIC card as the default route. When the system is
connecting with the extranet the data is forwarded through the default route.
Net-fault Tolerance Mode: The two NIC cards use the same IP address. You can
set the Main NIC to LAN1 or LAN2. By doing this, the device automatically enables
the standby NIC card ensuring the system runs normally in the event of a NIC card
failure.