Displaying And Changing Drive Parameters - Siemens SINAMICS Configuration Manual

Industrial security, medium-voltage converter
Hide thumbs Also See for SINAMICS:
Table of Contents

Advertisement

Security measures for SINAMICS
5.6 Web server
5.6.8.3

Displaying and changing drive parameters

● Each parameter list created is displayed as a separate tab in the "Parameter" display area.
● The list of parameters displayed is updated regularly. If an update is not possible, the
corresponding parameters are marked red.
● To change the parameter values of a parameter list, you need the appropriate "Write" rights.
For more information, refer to Section "Access protection for parameter lists in the web
server (Page 61)". In addition, the write and know-how protection apply.
Note
You can find detailed information in the chapter "Parameters for write protection and know-
how protection" of the converter List Manual:
● Parameters that can be changed with know-how protection active:
● Parameters that can only be read with know-how protection active:
● Only those parameter values in the parameter list can be changed for which there is a
"Change" button to the right of the line.
Changing parameter values
The required parameter list must be created in the web server.
1. Click the "Parameter" entry from the navigation.
2. In the "Parameter" display area, click the tab associated with the parameter list you wish
to view. The parameter list is displayed.
Figure 5-22
3. For the parameter containing values you wish to change, click the "Change" button. This
opens a dialog box for inputting the new value.
72
– Parameters with "WRITE_NO_LOCK"
– Parameters with "KHP_ACTIVE_READ"
Example: Changing drive parameters
Configuration Manual, 08/2017, A5E36912609A