Siemens SINAMICS Configuration Manual page 98

Industrial security, medium-voltage converter
Hide thumbs Also See for SINAMICS:
Table of Contents

Advertisement

Communication
A.1 Communication
Error
Significance
value
0x03
Invalid subindex.
0x04
No array.
0x05
Wrong data type.
0x06
Illegal set operation (only reset al‐
lowed).
0x07
Description element cannot be
changed.
0x09
No description data available.
0x10
Read job will not be executed.
0x0B
No operating priority.
0x0F
No text array exists.
0x11
Request cannot be executed due to
operating status.
0x14
Illegal value.
0x15
Response too long.
0x16
Illegal parameter address.
0x17
Illegal format.
0x18
Number of values inconsistent.
0x19
Drive object does not exist.
0x20
Parameter text cannot be changed
0x21
Service not supported.
0x65
Parameter presently deactivated.
0x6B
Write access for the enabled control‐
ler.
0x6C
Parameter %s [%s]: Unknown unit.
0x6D
Parameter %s [%s]: Write access only
in the commissioning state, encoder
(p0010 = 4).
0x6E
Parameter %s [%s]: Write access only
in the commissioning state, motor
(p0010 = 3).
98
Remark
Access to a subindex that does not exist.
Access with subindex to an unindexed parameter.
Modification access with a value that does not match the data
type of the parameter.
Modification access with a value not equal to 0 in a case
where this is not allowed.
Modification access to a description element that cannot be
changed.
Access to a description that does not exist (the parameter
value exists).
The read request is refused because know-how protection is
active.
Modification access with no operating priority.
Access to a text array that does not exist (the parameter value
exists).
Access is temporarily not possible for unspecified reasons.
Modification access with a value that is within the limits but is
illegal for other permanent reasons (parameter with defined
individual values).
The length of the present response exceeds the maximum
transfer length.
Illegal or unsupported value for attribute, number of elements,
parameter number, subindex or a combination of these.
Write request: Illegal or unsupported parameter data format.
Write request: A mismatch exists between the number of val‐
ues in the parameter data and the number of elements in the
parameter address.
You have attempted to access a drive object that does not
exist.
Illegal or unknown request ID
You have tried to access a parameter that, although available,
does not currently perform a function (e.g. n control set and
access to a V/f control parameter).
Write access is possible while the device is in the "Controller
enable" state.
Pay attention to the parameter attribute "changeable" in the
description of parameters in the converter List Manual (C1,
C2, U, T).
Configuration Manual, 08/2017, A5E36912609A