Communication
A.1 Communication
The required file is selected using parameter p8835. A POWER ON must be carried out after
selecting the desired UFW file. During the subsequent system boot, the corresponding UFW
file is loaded. The new selection then becomes active.
Table A-12
Functionality (p8835)
PROFINET device
PROFINET Gate
SINAMICS Link
EtherNet/IP
Modbus TCP
Customer-specific
from OEM directory
Path for the UFW file and folders on the memory card: /OEM/SINAMICS/CODE/CB/CBE20.UFW
1)
Identification of the firmware version
Using parameter r8858, the loaded firmware version of the PROFINET interface can be
identified uniquely.
Overview of important parameters
Note
For a description of the parameters, see the converter List Manual.
p8835
r8858[0...39]
r8859[0...7]
A.1.3.5
Communication via PROFINET Gate
Overview
The "PN GATE FOR SINAMICS" is a PROFINET solution for controller manufacturers or
mechanical equipment manufacturers who wish to simply integrate an interface to a
PROFINET network in their controllers. PROFINET communication is implemented via the
standard Ethernet interface of the controller without the need for a communication module or
an option module.
"PN GATE FOR SINAMICS" enables control devices with a standard Ethernet interface to be
connected isochronously via PROFINET with IRT to SINAMICS, and enables robotics or CNC
applications to be implemented with SINAMICS drives. In addition to SINAMICS, other
PROFINET devices (drives, distributed I/O, etc.) can be connected.
154
Functionality and selection in the pointer file
Contents
1
2
3
4
5
99
1)
CBE20 firmware selection
COMM BOARD read diagnostics channel
COMM BOARD identification data
Detailed information on this:
Chapter "Communication via PROFINET Gate"
Chapter "Communication via SINAMICS Link"
Chapter "Communication via EtherNet/IP"
Chapter "Communication via Modbus TCP"
Configuration Manual, 08/2017, A5E36912609A
Industrial Security