Siemens SINAMICS Configuration Manual page 40

Industrial security, medium-voltage converter
Hide thumbs Also See for SINAMICS:
Table of Contents

Advertisement

Security measures for SINAMICS
5.2 Write protection and know-how protection
6. Click "Specify".
The "Know-how Protection for Drive Unit - Specify Password" dialog box opens.
Figure 5-4
7. Enter your password. Length of the password: 1 ... 30 characters.
Recommendations for assigning a password:
– Only use characters from the ASCII character set.
– For an adequately secure password, the password must have a minimum length of 8
8. Enter it again in the "Confirm password" field and click "OK" to confirm the entry.
The dialog box is closed and the password is shown in encrypted form in the "Activate Know-
how Protection for Drive Object" dialog box.
9. If, despite active know-how protection, you permit diagnostic functions, activate the "Allow
diagnostic functions (trace and measuring functions)" option with a mouse click.
This allows the trace function, the measuring function and the function generator to be used
despite know-how protection.
10.The "Copy RAM to ROM" option is active by default and ensures that the know-how
protection is permanently stored in the Control Unit. If you want to use the know-how
protection temporarily, deactivate this option.
11.Click "OK".
Know-how protection is now activated. If larger data volumes are being encrypted, a
progress display informs that the encryption or the activation of the know-how protection
is still running.
The text "Know-how protected" then appears instead of the content in all protected
parameters of the expert list.
Note
For published DCC parameters, the entry "--" appears in the expert list instead of the text
"Know-how protected".
Preventing data reconstruction from the memory card
As soon as know-how protection has been activated, the drive unit only backs up encrypted
data to the memory card.
40
Setting the password
If you use arbitrary characters for the password, changing the windows language
settings after activating know-how protection can result in problems when subsequently
checking a password.
characters, and must include uppercase and lowercase letters as well as a combination
of letters, numbers, and special characters.
Configuration Manual, 08/2017, A5E36912609A
Industrial Security