Fault number
F08501
A08526
A50011
Overview of important parameters
Note
For a description of the parameters, see the converter List Manual.
Parameter
p0978[0...n]
p0922
p0999[0...99]
p8835
p8842
p8940[0...239]
p8941[0...3]
p8942[0...3]
p8943[0...3]
p8944
p8945
r8950[0...239]
r8951[0...3]
r8952[0...3]
r8954
r8955[0...5]
A.1.6
Communication via SINAMICS Link
A.1.6.1
Basic principles of SINAMICS Link
A drive unit (with a node number) most frequently comprises a Control Unit with a number of
connected drive objects (DOs). SINAMICS Link allows data to be directly exchanged between
up to 64 CU320-2 PN or CU320-2 DP Control Units or CUD. All of the participating Control
Units must be equipped with a CBE20 in order that SINAMICS Link functions. Possible
applications are, for example:
● Torque distribution for n drives
● Setpoint cascading for n drives
Industrial Security
Configuration Manual, 08/2017, A5E36912609A
Message
PN/COMM BOARD: Setpoint timeout
PN/COMM BOARD: No cyclic connection
EtherNetIP/COMM BOARD: Configuration error
Description
List of drive objects
IF1 PROFIdrive PZD telegram selection
List of modified parameters 10
CBE20 firmware selection
COMM BOARD activate send configuration
CBE2x Name of Station
CBE2x IP address
CBE2x Default Gateway
CBE2x Subnet Mask
CBE2x DHCP mode
CBE2x interfaces configuration
CBE2x Name of Station actual
CBE2x IP address actual
CBE2x Default Gateway actual
CBE2x DHCP Mode actual
CBE2x MAC address
Communication
A.1 Communication
203