Figure 5-26 Direct Mount Roller Chain - Siemens SITRANS FUP1010 Operating Instructions Manual

Ultrasonic flowmeters ip67
Hide thumbs Also See for SITRANS FUP1010:
Table of Contents

Advertisement

6. Finger-tighten the chain Tension Screw to secure the chain and tracks to the pipe.
FUP1010 IP67 Portable
Operating Instructions, 03/2012, A5E02951522-02
Chain Tension Screw
Chain Hook
Track Rail Assembly 1
Track Rail Assembly 2
Figure 5-26
Direct Mount Roller Chain
Note
For a vertical pipe installation, use a tie, tape or bungee cord to hold the two tracks in
place while chaining.
Centering Pin
Sensor 1 and Clamping Screw
Pipe
Sensor 2
Connecting
5.2 Sensor Wiring
57