5.2.6

Direct Mount

Direct Mount - Installation with EZ Clamp and Spacing Guide
The combination of EZ Clamp and spacer guide is the recommended way to mount Direct
Mode sensors. This method ensures that sensors will align exactly 180° from each other and
remain spaced the proper distance apart.
For Direct Mode mounting, a spacer bar is used to establish the distance between sensors
and a spacing guide is used to locate the sensors at the nine o'clock and three o'clock
positions. Should the distance between sensors be beyond the span of a spacer bar, a
measuring tape can be used. The Mylar spacing guide comes in various lengths and widths
to accommodate most pipe sizes.
5.08cm x 66.04cm) (2" x 26")
5.08cm x 114.3cm (2" x 45")
10.16 cm x 205.7cm (4" x 81")
10.16cm x 393.7cm (4" x 155")
15.2cm x 497.8cm (6" x 196")
Figure 5-15
Installation Procedure
1. Make a note of the Number Index displayed in the [Install Sensor] menu. Check to ensure
2. Temporarily position one of the sensors on the pipe where you will be mounting it. Ensure
3. Prepare the area you marked by degreasing the surface and removing any grit, corrosion,
FUP1010 IP67 Portable
Operating Instructions, 03/2012, A5E02951522-02
Mylar Spacing Guide
that you have a matched set of sensors. They both should have the same S/N number
but marked with either an "A" or "B" (e.g., 100A and 100B).
that this is a smooth area without any raised areas (seams, etc.) With a pencil or chalk,
mark a generous area around all sides of the sensor. Remove the sensor.
rust, loose paint or surface irregularities with the abrasive pipe conditioning material
provided.
Spacing Guide Sizes