Siemens SITRANS FUP1010 Operating Instructions Manual page 67

Ultrasonic flowmeters ip67
Hide thumbs Also See for SITRANS FUP1010:
Table of Contents

Advertisement

To disable the ZeroMatic function:
1. Select the [Install Sensor] menu cell from the [Dual Path Flow] menu.
2. Scroll down to the [Zero Flow Adjust] menu cell by pressing <Up/Down Arrow>.
3. Invoke the ZeroMatic initial makeup procedure as previously described above.
4. While ZeroMatic initial makeup is running, press <Left Arrow> to abort the process
5. The screen will return to the [Dual Path Flow] menu and highlight the [Operation Adjust]
FUP1010 IP67 Portable
Operating Instructions, 03/2012, A5E02951522-02
Note
The highlighted [ZeroMatic] menu item is the only indication that ZeroMatic is functioning.
thereby disabling the function.
menu cell.
Connecting
5.3 Zero Flow Adjust Menu
65