Siemens SITRANS FUP1010 Operating Instructions Manual page 18

Ultrasonic flowmeters ip67
Hide thumbs Also See for SITRANS FUP1010:
Table of Contents

Advertisement

Description
3.3 Theory of Operation
∅° = sin
T
= 2 * ID / (VOS * cos ∅)
L
V
= V
F
Flow Profile Compensation
Another important consideration is that the ultrasonic flow meter has to compensate for the
flow profile to maintain calibration accuracy. Shown below is a graphic of a "fully-developed"
flow profile. Note that the fluid velocity increases toward the center (axis) of the flow stream.
Fluid velocity near the axis of the flow stream tends to be greater.
16
Velocity of Sound
Flow Vector
Pipe ID
WideBeam Sensors
(VOS / V
)
-1
phase
* DT / (2 * TL)
phase
Where:
VOS = Velocity of sound in liquid
V
phase
ID = Pipe inside diameter
T
= Transit time in liquid
L
DT = Measured Transit-Time difference
V
= Flow Velocity
F
Operating Instructions, 03/2012, A5E02951522-02
= Phase velocity of sensor
FUP1010 IP67 Portable

Advertisement

Table of Contents
loading

This manual is also suitable for:

7me3510

Table of Contents