Contents
Equipment specification
of power
Range
of
applicable
outer diameter
Connector name
Applicable Connector
Contents
Applicable Cable
Applicable terminal
Method of processing
connector
(1) Ethernet cable
・ Ground wire more than 1.5□mm
・ FG terminal M4nut.
・ The DC -48V power supply voltage for AP-IFU shall be SELV or TNV-1 depending on the
network environment (0 or 1) acc. to IEC62102.
・ The Equipment for connection to AP-IFU Ethernet-interface(RJ-45) shall be appropriate to
connect to TNV-1 circuits.
・ For the connection Terminal Equipment to AP-IFU and a cables suitable for outdoor use
shall be installed.
・ When opening the AP-IFU cover, make sure that the four special screws are loosened
completely. Forcing open the cover may damage it.
・ +16VDC to be supplied to the AP-RFU is superimposed on the signals in the IF cable.
Turn off the power to the AP-IFU when installing or removing the IF cable. Otherwise, the
unit may be damaged.
・ Cover the cable connection with a cold-shrinkable sleeve to make it waterproof.
Otherwise, water may get in the connection.
・ After you opened the AP-IFU cover, make sure to secure it using the stopper. Otherwise,
you may get hurt. To close the cover, be sure to return the stopper to the original position.
・ For the connection AP-IFU to AP-RFU and a coaxial cable suitable for outdoor use shall
be installed.
(2) Power cable
Connect the power cable connector.
DC-48V,35W(Max)
Φ7.0mm – Φ8.5mm
NRW-203-RM-ULCSATUV (Nanaboshi Electric MFG Co.,LTD.)
NRW-203-PF8-ULCSAUV (Nanaboshi Electric MFG Co.,LTD.)
(This connector is supplied with AP-IFU.)
(3) Ground wire
Connect the ground wire.
Ground wire more than 1.5□
FG terminal M4nut.
See Subsection 5.5.1
5-60