7.2. Connecting the WT Local Management Tool
Connect the local management tool terminal to the PC port of the WT adapter (Figure 7-1) using a
straight Ethernet cable.
Ethernet cable (Straight)
local management tool(PC)
Master
IP address: 192.168.1.200
Subnet mask: 255.255.255.0
Slave
IP address: 192.168.1.201
Subnet mask: 255.255.255.0
・ When changing the IP address of the unit, set the IP address of the local
management tool (PC) to an IP address belonging to the same network.
・ When changing the IP address of the unit, restart the power of the hub if the unit is
connected to the local management tool (PC) via a hub (because MAC address
learning may fail and the connection may be dropped).
WT adapter
DC24V
AC Adapter
Figure 7-1 Connection
7-112
Ethernet cable (Straight)
AC100∼240V
initial values
IP address:192.168.1.100
Subnet mask:255.255.255.0