5.5.1. Connecting the Power cable connector

The connector manufacturer (Nanaboshi Electric MFG Co., Ltd.) recommends the following
method of cable connection.
(1) Disassemble the connector, as shown here.
(a) Remove the insert assembly from the end bell by turning the assembly counterclockwise.
(b) Loosen the clamping nut to remove the cable packing.
(2) Pass the cable through the disassembled parts in the sequence shown here.
Note:
Be sure that all the parts are placed in the specified sequence and in the
correct direction.
(3) Peel the cable sheath and wires according to the dimensions specified here.
Sheath
Cable outside diameter
7.0 to 8.5 mm
(4) Process the ends of the cable's core wires and pretin them.
Note:
Do not pretin the cable sheath.
Note:
When the cable core is pretinned, it should be uniform everywhere and smaller
than the diameter of the opening in the contact.
Clamping nut
Cable pakkin
Clamping nut Cable pakkin
Cable
Core wire
18mm
Iron tip
Cable
Core
wire
End bell
Insert assembly
End bell
Cable
Conductor cross-sectional area 2 mm
7mm
Solder
Contact
5-61