5.2.2. Installing the AP-RFU (Sectoral-Horn Antenna)
The mounting braket are attached AP-RFU.
(1)
As shown in Figure 5-3, loosen the bolts (a), (b), and (c) and install the AP-RFU mounting
bracket on the pole. Next, tighten the bolts (a), (b), and (c). (Recommended tightening torque:
8.5 N-m)
Applicable pole diameter: From 31.8mm to 38.1mm
(2)
As shown in Figure 5-4, finger-tighten the bolts (f) in the threaded holes on the rear of the
AP-RFU.
Figure 5-4 Finger-tightening the Mounting Bolts to the AP-RFU
(e)
(d)
Figure 5-3 Installing the AP-RFU Mounting Bracket on the Pole
5-48
(a)
(b)
(c)
(f)