3.2.3. Operations and Indications
3.2.3.1. Indications
h
⑧
a
①
LED
a
POWER
b
ETHER 1
c
ETHER 2
d
IFU STATE
e
RFU ALARM
f
ETHER1 AUTO
g
ETHER2 AUTO
h
RST
26G-2-AP-PWR
制御盤LED部拡大図
b
c
e
d
②
③
④
⑤
Figure 3-5 AP-IFU Operation and Indication Panel
Table 3-1 AP-IFU Indications
Lit green: Power on
Extinguished: Power off
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 4)
Lit green: ETHER link established
Flashing green: ETHER signal sent or received
Extinguished: ETHER link down (See Table 3-3, 5)
Lit red: IFU alarm (See Table 3-3, 2)
Flashing green: Normal (CPU running)
Flashing orange: During initialization
Lit red: RFU alarm (Cause: RFU failure (See Table 3-3, 1) or
communication error between the IFU and RFU (See Table 3-3, 3))
Extinguished: RFU alarm cleared
Lit green: AUTO (ETHER1 AUTO switch set to AUTO)
Extinguished: 100BASE full duplex
Lit green: AUTO
Extinguished: 100BASE full duplex
Unit reset switch
100
AUTO
FULL
f
⑥
ETHER1 AUTO ETHER2 AUTO
State indication
3-30
26G-2-AP-CNT
100
AUTO
FULL
g
⑦