JRC NTG337-EL0 Instruction Manual page 154

Fwa system
Table of Contents

Advertisement

(4) Method of adjustment for near-distance installation
If circuit design calls for a receive level of -35 dBm or higher, use the following procedure:
-
Start the WT Local Management Tool and select P-P mode.
On the Master Setup screen in the master station in P-P mode, change "Trans.Level" from
-
14[dBm] to -6[dBm]. After the change, click the SETUP button.
The procedure is shown in Figure 7-33.
Figure 7-33 Setting "Trans.Level" for the WT (Master)
On the Slave Setup screen in the slave station in P-P mode, change "Trans.Level" from
-
14[dBm] to -6[dBm]. After the change, click the SETUP button.
The procedure is shown in Figure 7-34.
Figure 7-34 Setting "Trans.Level" for the WT (Slave)
OFF
7-131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ntg335-el0Nt337-xl2Ntg337-xl0Ntg337-el2Ntg335-el2

Table of Contents