6.11. When you use the cable with the LAP sheath for outdoor

1.Processing of LAP sheath
-
The LPA sheath is peeled off from the cable point to 120mm.
-
It cuts it in the part peeled off when there is drain wire.
2.Processing of cutting part
-
To prevent water being infiltrated in the wire, the self-bonding tape is rolled in the part
where the LAP sheath was peeled off as shown in the figure below.
-
The Ether plug is installed with the normal temperature shrinkage sleeve and Spasa
passed.
Spacer
Connector
Push
3.Fixation of cable Ethernet、Installation of Spacer and normal temperature shrinkage sleeve
-
See「6.9. Waterproofing WT small window」
4.Wrapping of PVC tape for protection
- It wraps until the self-bonding tape in the LAP sheath processing part is completely hidden
120mm
Drain Wire
50mm
25
6-104
The cable with the LAP sheath
Drain wire is cut on the LAP sheath side.
Self-bonding
25