Manageable Mosaic switch Installation and User Guide
4 4 R e m o t e D e v i c e C o n f i g u r a t i o n
R e m o t e D e v i c e C o n f i g u r a t i o n
Before configuring an IP entity on the network, and in order to remotely manage and monitor a device,
the IP parameters of the device must be defined. In manageable Mosaic switch this is done by running
an application on the PC. The application performs auto discovery of all connected devices.
In manageable Mosaic switch, the RS232 CLI (command-line interface) serial cable is required to
perform remote IP configuration of local devices.
The
manageable Mosaic switch is supplied without the CLI serial cable. To remotely manage and
monitor a device without the CLI serial cable, the Legrand LCS
installed. To configure the IP parameters, the user must first connect the CLI cable, run the Terminal
Emulation application to log on to the manageable Mosaic switch unit, and then configure the network
IP parameters.
4.1 Configuration via the Terminal Emulation Application
NOTE: This section describes the procedure for running the HyperTerminal emulation
application. The procedure may vary for other applications.
To set up the HyperTerminal application:
1. Start HyperTerminal application used by PC. (Legrand recommends Tara Term)
2. Connect the CLI serial cable acquired from Legrand between the switch CLI port and a
serial port on your computer. (if used Serial to USB adaptor, connect cable to one of
the computer USB ports)
3. From computer, Device manager, identify the port (COM) used for the CLI cable and
confirm the setting of port to follow the setting as in next figure.
4. Reset the power on the manageable Mosaic switch switch by pressing the reset push
button (, or carefully disconnect and reconnect the power cable if it was already
connected). The current definitions will appear as shown in the boot sequence below.
Figure 4-1 COM Properties Window
SUMMARY
2
- FTTO Init application must be
Page 45 of 87