Mounting

This section outlines the various mounting options available for the SSP 7.1.
Tabletop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in any convenient
location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of
these products in a rack:
1.
2.
3.
4.
5.
Rack Mounting Procedure
Extron provides a range of rack-mounting kits (see www.extron.com). To mount the SSP 7.1 on
a rack shelf, follow the instructions provided with the kit.
Under-desk Mounting
Extron provides a range of kits for mounting equipment under a desk or podium (see
extron.com). To mount the SSP 7.1 under a desk or podium, follow the instructions provided
with the kit.
Tabletop Placement
Rack Mounting
Under-desk Mounting
Elevated operating ambient temperature — If the unit is installed in a closed or multi-
unit rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore, install the equipment in an environment
compatible with the maximum ambient temperature (Tma: +122 °F, +50 °C) specified by
Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets adequate
air flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the effect
that circuit overloading might have on overcurrent protection and supply wiring. Appropriate
consideration of the equipment nameplate ratings should be used when addressing this
concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment.
Pay particular attention to supply connections other than direct connections to the branch
circuit (such as the use of power strips).
www.
SSP 7.1 • Mounting