Mounting the Quantum Ultra Series

The Quantum Ultra Series processor can be placed on a tabletop or mounted in a rack
(recommended).
CAUTION: The Quantum Ultra 610 and Ultra II 610 chassis is very heavy. When it is
ATTENTION :

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines pertain to the installation of the
Quantum Ultra Series processor into a rack:
fully populated with input and output cards, its weight can be up to 87 lbs (39.5 kg).
It is strongly recommended that you seek assistance with lifting or moving the unit.
Le processeur Quantum Ultra est très lourd. Lorsqu'il est
entièrement équipé de cartes d'entrée et de sortie, son poids peut être jusque
39.5 kg (87 lbs).
Il est fortement recommandé que vous soyez assisté lorsque vous soulevez ou que
vous déplacez l'unité.
Elevated operating ambient temperature — If the equipment is installed in a
closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore, consider installing the
equipment in an environment compatible with the maximum ambient temperature
(TMA) of 95 ºF (35 ºC).
Reduced air flow — Install the equipment in the rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit,
consider the connection of the equipment to the supply circuit and the effect that
circuit overloading might have on overcurrent protection and supply wiring. Consider
equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct
connections to the branch circuit (such as the use of power strips).
Quantum Ultra Series Videowall Processing Systems • Reference
114