Reset Features

Reset button and LED — Pressing this recessed button causes various product settings
to be reset to the factory defaults. The green Reset LED (rear panel of the IPL EXP S2,
IPL EXP S5, IPL EXP 200) or Power LED (front panel of the IPL EXP RIO8) blinks depending
on the selected reset mode (see
table

Mounting

Mounting Options

Optional 1U rack shelves are available for use with all IPL EXP models. A variety of
rack mounting bracket kits and furniture mounting kits are available for use with the
IPL EXP RIO8.
See the product-specific page at
mounting your expansion interface. Visit the product-specific page on the Extron website
(www.extron.com) for a list of compatible accessories for mounting your control processor
or call a support representative to find out which kit to order for your installation.
Read the instructions that are included with the rack shelf or mounting kit for installation
procedures and see the UL rack mounting guidelines below for safe installation. Then
securely mount the control system expansion interface and other devices and attach cables
using the wiring section (see
wiring guide.

UL Rack Mounting Guidelines

The following
IPL EXP I/O Series expansion interfaces in a rack.
1.
2.
3.
4.
5.
starting on page 29 for details).
Optional furniture mounting bracket kits are available for use with the IPL EXP RIO8 .
All other models come with a ZipClip 200 mounting bracket, which can be mounted to
to the following items:
tabletop
optional equipment rack shelf
Ports, Addressing, and Connections
Underwriters Laboratories (UL)
Elevated operating ambient temperature — If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be
greater than room ambient temperature. Therefore, install the EXP in an environment
compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified
by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (such as use of power strips).
IPL EXP I/O Series • Hardware Features and Installation