Mounting

This section outlines the various options for mounting the TLI Pro 101.

Tabletop Placement

Attach the four provided rubber feet to the bottom of the unit and place it in any convenient
location.

Rack Mounting

Underwriters Laboratories Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of
these products in a rack:
Elevated operating ambient temperature — If the unit is installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be greater
than room ambient temperature. Therefore, install the equipment in an environment compatible
with the maximum ambient temperature (Tma: +122 °F, +45 °C) specified by Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets adequate
air flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading
does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring. Give
appropriate consideration to the equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment.
Pay particular attention to supply connections other than direct connections to the branch
circuit (such as the use of power strips).

Rack Mounting the TLI Pro 101

The TLI Pro 101 can be mounted on any Extron standard rack system (not provided). See
www.extron.com

Under-desk Mounting

Mount the unit under a desk or podium, using an Extron under-desk mounting kit (not
provided). See
included with the kit.
Tabletop Placement
Rack Mounting
Under-desk Mounting
for a list of appropriate kits and follow the instructions included with the kit.
www.extron.com
for a list of appropriate kits and follow the instructions
TLI Pro 101 • Mounting
29