Installation Overview

To install and set up an IPL T S interface, follow these steps:
1.
2.
3.
4.
5.

Mounting the IPL T S Interface

UL Guidelines for Rack Mounting

The following Underwriters Laboratories (UL) guidelines pertain to the installation of an IPL T
S Series unit onto a rack.
1.
2.
3.
4.
Installation Overview
Mounting the IPL T S Interface
Rear Panel Features and Cabling
Operation
Turn all of the equipment off. Make sure that the video sources (DSS, cable boxes, or
other devices), the IPL T S unit, the output devices (monitors, VCRs, projectors, and so
on) and the serial controller are all turned off and disconnected from the power source.
Mount the IPL T S interface (see
Attach the cables (see
Connecting the
Connect power cords and turn on the devices in the following order: output devices
(projectors, monitors, speakers), IPL T S interface, serial controller or computer (PC),
then input devices (DSS, cable boxes, and so on).
Configure the IPL T S interface through DataViewer or Telnet, then access the unit using
an Internet browser.
Elevated operating ambient — If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consider installing the equipment in an environment compatible with
the maximum ambient temperature specified by the manufacturer [Tma =
(0 to +50 °C)].
Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Mounting the IPL T S
Interface).
Hardware).
IPL T S Series • Installation and Operation
+32 to +122 °F
4