Mitsubishi M80 series Connection And Set Up Manual page 74

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
[Connector]
(3)
(1)
(5)
(4)
(2)
Arrow A
Connector
No.
name
(1)
USB_F
(2)
USB_B
(3)
BL
(4)
SDC_F
(5)
SDC_B
(6)
DCIN
(7)
EMG
(8)
OPTH1
(10) BAT
(11) CJ71
(12) RIO1
Refer to "General Specifications: Control Unit [M800S]" for details on the connectors.
(6)
(8)
(23)
Function
Front-side USB memory I/F
Display unit backlight I/F
Front-side SD card I/F
Back-side SD card I/F
24VDC input
External emergency stop input
High-speed optical servo
communication
Battery I/F
Operation panel I/O unit I/F
Remote I/O 2.0 communication
(7)
(22)
(12)
(14)
(10)
(11)
(13)
(15) (16)
(17)
Connector
No.
name
(13) RIO2
Remote I/O 2.0 communication
(14) MENUKEY
Menu key I/F
Encoder input 1ch
(15) ENC
(5V manual pulse generator input
2ch)
(16) SKIP
SKIP input 8 points
(17) SIO
RS-232C communication 2ch
(18) LAN1
Ethernet communication
(19) LAN2
Ethernet communication
(20) FG
FG terminal
(21) LCD
Display unit signal I/F
(22) EXT_P
Communication expansion unit I/F
(23) TP
Touch panel I/F
37
A
(21)
(18)
(19) (20)
Function
IB-1501269-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents