Mitsubishi M80 series Connection And Set Up Manual page 231

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
7 Connection of Control Unit
(2) When using the MDS-E/EH unit together
The power (L+, L-) can be supplied to other drive unit by using the power supply part which is built into MDS-EM/
EMH. Connect so that the end of NC communication bus is MDS-EM/EMH.
Connected
to the NC
Optical
communication
cable
The optical communication cables from the NC to the
final drive unit must be within 30m.
CAUTION
There is a limit to the combination of the drive unit.
Refer to "7.3 Selection of the Additional Axis Drive Unit" in MDS-EM/EMH Series Specifications Manual (IB-
1501238(ENG)).
IB-1501269-F
MDS-E/EH-V1
MDS-E-SP2
5th axis
6th/7th axis
When using MDS-EM/EMH drive unit together with MDS-E/EH
MDS-E/EH-SP
MDS-EM/EMH-SPV3
Spindle:1st axis
8th axis
Servo:2nd/3rd/4th axis