17 Setting the Hardware
(7) Up to 24 stations can be specified for high-speed input/output specification each for input and output. If 25 or more
stations are specified, the alarm "Y05 Initial parameter error" will be issued.
(8) High-speed input/output specification can be set by R registers below as well as the RIO assignment parameters.
Channel No.
High-speed input
specification
RIO1
High-speed
output
specification
High-speed input
specification
RIO2
High-speed
output
specification
High-speed input
specification
RIO3
High-speed
output
specification
(Note 1) Turn the power OFF and ON after the R register settings to enable the settings.
(Note 2) One bit of each R register is equivalent to one station. The high-speed input/output specification can
be performed by turning ON the R register bits of the stations to be input or output with PC high
speed. To output the 10th station of RIO1 at high speed, for instance, turn BIT9 of R30544 ON.
(Note 3) High-speed input/output designation is disabled for the system-occupied stations of RIO3 and
operation panel I/O unit-connected channels. Even when the BIT6 to BITD of R30552 and R30568
are turned ON, they will be invalid.
(Note 4) The above settings are invalid with fixed device assignment.
(9) In the following cases, the alarm "Y05 Initial parameter error" will be issued when the power is turned ON. The
number of the RIO assignment parameter with illegal setting state will be displayed.
(a) The value outside the range of setting has been set to the RIO assignment parameter (except #53001 RIO dev
assign).
(b) Two or more stations of the target channel No. and the target station No. are set redundantly to the RIO
assignment parameters.
(Example)
The power is turned ON in a state where the 1st and 2nd station of RIO1 are set redundantly to the RIO
assignment parameter #1 to #5 as shown in the table below. (Both the 1st and 2nd stations are
connected to NC control unit.)
Parameter set No.#n
Result:
The parameter number (53031) of "Target channel #3" will be displayed on the alarm "Y05 Initial parameter
error". Duplication error of RIO1 second station will be detected first because the RIO assignment parameter is
checked from the top. Between the parameter set #2 and #3 to which second station of RIO1 are set,
parameter set #3 which is the latter will be displayed as the alarm.
(c)
A PLC device outside the assignable range has been set to the RIO assignment parameter.
(d) 25 or more stations have been specified with the high-speed input or output with the RIO assignment
parameters.
IB-1501269-F
1 to 8
9 to 16
R30544
R30544
low-order
high-order
low-order
R30560
R30560
low-order
high-order
low-order
R30548
R30548
low-order
high-order
low-order
R30564
R30564
low-order
high-order
low-order
R30552
R30552
low-order
high-order
low-order
R30568
R30568
low-order
high-order
low-order
Target channel No.
#n (parameter No.)
1
1(#53011)
2
1(#53021)
3
1(#53031)
4
1(#53041)
5
1(#53051)
Station No.
17 to 24
25 to 32
33 to 40
R30545
R30545
R30546
high-order
low-order
R30561
R30561
R30562
high-order
low-order
R30549
R30549
R30550
high-order
low-order
R30565
R30565
R30566
high-order
low-order
R30553
R30553
R30554
high-order
low-order
R30569
R30569
R30570
high-order
low-order
Target station No.
#n (parameter No.)
0(#53012)
RIO1 1st station is set
1(#53022)
RIO1 2nd station is set
1(#53032)
RIO1 2nd station is set
0(#53042)
RIO1 1st station is set
0(#53052)
RIO1 1st station is set
340
41 to 48
49 to 56
57 to 64
R30546
R30547
R30547
high-order
low-order
high-order
R30562
R30563
R30563
high-order
low-order
high-order
R30550
R30551
R30551
high-order
low-order
high-order
R30566
R30567
R30567
high-order
low-order
high-order
R30554
R30555
R30555
high-order
low-order
high-order
R30570
R30571
R30571
high-order
low-order
high-order
Setting state

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents