4 General Specifications
Unit name
Item
Ambient
temperature
Ambient
humidity
Vibration resistance
Shock resistance
Working atmosphere
Altitude
Power supply voltage
General
Specifications
Current consumption
Heating
value
Mass
Outline
dimension
W×H
(Note 1) "Short term" means roughly within one month.
(Note 2) The current consumption of the keyboard unit and the operation panel I/O unit (control section) are included in
that of the control unit. Current consumption for the I/O circuit needs to be separately calculated based on the
number of points used and its load.
(Note 3) For the heating value of the I/O circuit, calculate with the number of points used.
(Note 4) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000
meters above sea level. Refer to the manual of drive unit for details.
(Note 5) 24V power input is not required for FCU8-KB931.
IB-1501269-F
Keyboard unit
FCU8-KB026/KB028 : (8.4-type)
FCU8-KB029 : (8.4-type/vertical
arrangement)
FCU8-KB041/KB046 : (10.4-type)
Type
FCU8-KB047 : (10.4-type/vertical
arrangement)
FCU8-KB048 : (10.4-type)
FCU8-KB083 : (15-type/vertical
arrangement)
During
operation
During
storage
Long term
Short term
5VDC
(max)
FCU8-KB026/KB028 : 0.75
FCU8-KB029 :1.0
FCU8-KB041/KB046 : 0.8
(kg)
FCU8-KB047 : 1.3
FCU8-KB048 : 1.4
FCU8-KB083 : 1.5
FCU8-KB026/KB028 : 140×200
FCU8-KB029 : 260×140
FCU8-KB041/KB046 : 140×220
(mm)
FCU8-KB047 : 290×160
FCU8-KB048 : 230×220
FCU8-KB083 : 400×140
Operation panel I/O unit Machine operation panel
FCU8-DX750
FCU8-DX760
FCU8-DX761
0 to 58°C
-20 to 60°C
10 to 75% RH (with no dew condensation)
10 to 95% RH (with no dew condensation) (Note 1)
2
4.9m/s
or less
2
29.4m/s
or less
No corrosive gases, dust or oil mist
Operation/Storage: 1000 meters or less above sea level,
Transportation: 13000 meters or less above sea level
5VDC/3.3VDC
(Supply from Control Unit)
- (Note 2)
1W
4W (Note 3)
FCU8-DX750 : 0.4
FCU8-DX760 : 0.5
FCU8-DX761 : 0.5
116×179
22
FCU8-KB921
FCU8-KB922
FCU8-KB923
FCU8-KB924
FCU8-KB931
24VDC (Note 5)
0.3A (Note 5)
7.2W
FCU8-KB921/KB922 : 1.1
FCU8-KB923/KB924 : 1.2
FCU8-KB931 : 0.5
FCU8-KB921/KB922 :
260×140
FCU8-KB923/KB924 :
290×140
FCU8-KB931 : 140×140