4 General Specifications
(5) MPG (Manual pulse generator input)
5V manual pulse generator and 12V manual pulse generator can be connected to this connector.
10
20
1
0V
2
I
HA3A
3
I
HA2A
4
I
HA1A
5
0V
6
O
+12V
7
NC
8
NC
9
O
+12V
10
O
+5V
- Connect connector case with FG pattern.
<Cable side connector type>
Plug : 10120-3000PE
Shell : 10320-52F0-008
Recommended manufacturer : 3M
(Note)
1
11
11
0V
12
I
HA3B
13
I
HA2B
14
I
HA1B
15
0V
16
O
+12V
17
NC
18
NC
19
O
+5V
20
O
+5V
When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws
too tightly otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05N·m)