Mitsubishi M80 series Connection And Set Up Manual page 158

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
[Connector]
(1)
(Note)
On this unit, EtherNet/IP function is supported by the "LAN1" port only. LAN2 does not support EtherNet/
IP function.
CAUTION
Do not apply any voltage to the connectors other than voltage specified in this manual. Failure to observe this
could cause bursting, damage, etc.
Connect the cables to the designated connectors. Incorrect connections could damage the device.
(1) LAN1 (EtherNet/IP communication)
8
1
1
O
TXD+
2
O
TXD-
3
I
RXD+
4
NC
- Connect connector case with FG pattern.
<Cable side connector type>
Connector : J00026A0165
Recommended manufacturer : Japan Telegärtner
Connector
No.
name
(1)
LAN1
EtherNet/IP communication
5
NC
6
I
RXD-
7
NC
8
NC
121
Function
IB-1501269-F

Hide quick links: