Mitsubishi M80 series Connection And Set Up Manual page 105

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(a) Outline of digital signal output circuit
Use within the specification ranges shown below.
Output circuit
Stabilized
power supply
24VDC(+)
Output conditions
Insulation method
Rated load voltage
Max. output current
Output delay time
IB-1501269-F
CJ38/CJ40/CJ42
DOCOM
Load
0V
FG
Non-insulation
24VDC
0.2A/point
[Total output current of whole unit]
- For FCU8-DX750/DX761: 3.8A or less
- For FCU8-DX760: 5.7A or less
40μs
68
Y200
Y23F
Y260
Y27F
0V
Control
circuit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents