4 General Specifications
(10) SDI2 (Safety DI input)
B1
A1
B
6
COM+
 
5
COM+
 
4
COM+
 
3
COM+
 
2
COM+
 
1
COM+
 
<Cable side connector type>
Connector : 175362-1 (2-pole type)
Connector : 175363-1 (4-pole type)
Connector : 1318095-1 (6-pole type)
Contact : 175218-2
Recommended manufacturer : Tyco Electronics
(a) Outline of digital signal input circuit
Refer to "(9) SDI1 (Safety DI input)".
(11) SDO1 (Safety relay output)
(12) SDO2 (Safety relay output)
B1
A1
B
4
  SYR03A
3
  SYR02A
2
  SYR01A
1
  SYR00A
<Cable side connector type>
Connector : 178289-4
Contact : 175218-2
Recommended manufacturer : Tyco Electronics
IB-1501269-F
B6
A6
A
6
I
SX07B
5
I
SX07A
4
I
SX06B
3
I
SX06A
2
I
SX05B
1
I
SX05A
B4
A4
SDO1
A
4
  SYR03A
4
3
  SYR02A
3
2
  SYR01A
2
1
  SYR00A
1
102
SDO2
B
A
  SYR03B
4
  SYR03B
  SYR02B
3
  SYR02B
  SYR01B
2
  SYR01B
  SYR00B
1
  SYR00B