Mitsubishi M80 series Connection And Set Up Manual page 369

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
17 Setting the Hardware
(Note 1) A remote I/O unit has two slide switches (station No. group setting switches) and one rotary switch
(station No. setting switch) for station No. setting, which link the device Nos. (with X/Y). Set the slide
switches and the rotary switch as follows.
Slide switch
1
2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
The station Nos. of FCU8-DX561 can be set in two ways according to the slide switch (station No. setting
switch). Set the knob to the left for the station No. setting 1 and to the right for the station No. setting 2.
Station No. setting 1
DI/DO
Safety DI (SX00A to SX07A)
/Safety relay output (SY00A to SY03A)
/Relay feedback (SX08A to SX0BA)
Safety DI (SX00B to SX07B)
/Safety relay output (SY00B to SY03B)
/Relay feedback (SX08B to SX0BB)
(Note 2) Refer to "17.6.4 PLC Device Assignment of Digital Signal (DI/DO)" for device No. assignment.
IB-1501269-F
Rotary switch
FCU8-DX213/DX213-1/
DX220/DX202
0
1
1
2
2
3
F
16
0
17
1
18
2
19
F
32
0
33
1
34
2
35
F
48
0
49
1
50
2
51
F
64
Station No. setting 2
Device
Station No.
FCU8-DX230/DX231/
DX654/DX654-1
1,2
2,3
3,4
16,17
17,18
18,19
19,20
32,33
33,34
34,35
35,36
48,49
49,50
50,51
51,52
64,1
Station No. setting 1 Station No. setting 2
Station No. 1
Station No. 2
Station No. 3
332
FCU8-DX408
1,2,3
2,3,4
3,4,5
16,17,18
17,18,19
18,19,20
19,20,21
32,33,34
33,34,35
34,35,36
35,36,37
48,49,50
49,50,51
50,51,52
51,52,53
64,1,2
Station No. 4
Station No. 5
Station No. 6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents