Mitsubishi M80 series Connection And Set Up Manual page 175

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(4) ON switch
NO
a
b
NC
a
I
Lamp terminal (+)
b
O
Lamp terminal (-)
NO
O
Contact 1 (A contact)
NC
O
Contact 2 (B contact)
(Note)
Connect LGCON terminal and ON terminal of G170 cable to NO terminal of ON switch.
<Switch type>
Switch : AH165-SLW11X3/0063
Recommended manufacturer : IDEC
Connection : Terminal
<Cable side connector type>
Connector: Faston terminal #110
Recommended manufacturer : -
(5) OFF switch
NO
NC
NO
O
Contact 1 (A contact)
NC
O
Contact 2 (B contact)
(Note)
Contact LGCOFF terminal and OFF terminal of G170 cable to NO terminal of OFF switch.
<Switch type>
Switch : AH165-SLB11X3/0063
Recommended manufacturer : IDEC
Connection : Terminal
<Cable side connector type>
Connector: Faston terminal #110
Recommended manufacturer : -
IB-1501269-F
Switch
NO
NC
NO
NC
NC NO
NO
Switch
NC
NO
NC
NC NO
138