Mitsubishi M80 series Connection And Set Up Manual page 170

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(1) DCIN (24VDC input)
1
1
I
+24V
2
0V
3
FG
<Cable side connector type>
Connector : 2-178288-3
Contact : 1-175218-5
Recommended manufacturer : Tyco Electronics
(2) DCOUT (24VDC output)
1
1
O
+24V
2
0V
3
FG
<Cable side connector type>
Connector : 2-178288-3
Contact : 1-175218-5
Recommended manufacturer : Tyco Electronics
(3) RIOIN (Remote I/O 2.0 communication (input))
(4) RIOOUT (Remote I/O 2.0 communication (relay))
Up to 64 remote I/O stations can be connected.
X
B
A
1 2 3
A
1
I/O
TXRXD
2
NC
3
FG
<Cable side connector type>
Connector : 1-1318119-3
Contact : 1318107-1
Recommended manufacturer : Tyco Electronics
(5) FG (FG terminal)
3
3
B
1
I/O
TXRXD*
2
0V
3
NC
133