Mitsubishi M80 series Connection And Set Up Manual page 106

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
(Note 1) When using an inductive load such as a relay, always connect a diode (voltage resistance
Stabilized
power supply
24VDC(+)
(Note 2) When the rush current exceeds the maximum output current, always connect a protective
Stabilized
power supply
24VDC(+)
100V or more, twice or more the load current) in parallel to the load.
DOCOM
Inductive load
0V
FG
Diode
resistor (R=150Ω) serially to the load to suppress rush currents. Make sure that the current is
less than the maximum output current including the momentary current.
DOCOM
Load
Resistor
0V
FG
Y
Y
69
IB-1501269-F