M800S/M80 Series Connection and Setup Manual
27 Adjust S-analog Screen
The spindle analog output adjustment is carried out on this screen.
(1)
(2)
(3)
(4)
Display items
Display item
(1)
Parameter No.
(2)
Adjustment item name
(3)
Adjustment data
(4)
Current adjust data
(5)
Operation procedure
Menus
Menu
Auto
This carries out automatic adjustment of the spindle analog output.
adjust
Manual
This carries out manual adjustment of the spindle analog output.
adjust
Voltage
This is used during manual adjustments to adjust downward in decrements
-10
of 10.
Voltage
This is used during manual adjustments to adjust downward in decrements
-1
of 1.
Voltage
This is used during manual adjustments to adjust upward in increments of
+1
1.
Voltage
This is used during manual adjustments to adjust upward in increments of
+10
10.
IB-1501269-F
This is a number to be used when inputting/outputting the parameters.
For manual adjustments, this uses the [ ↑ ] [ ↓ ] keys to move the cursor to the setting item
to be adjusted.
The cursor does not display during automatic adjustments.
This displays the names of the spindle analog adjustment items.
This displays the setting data for each adjustment item.
This displays data which is being adjusted manually. (Display only during a manual
adjustment.)
This displays the operation procedures for automatic and manual adjustments.
Details
438
Details
Reference
Performing Automatic
Adjustments
Performing Manual Adjustments
(5)