Mitsubishi M80 series Connection And Set Up Manual page 68

Hide thumbs Also See for M80 series:
Table of Contents

Advertisement

M800S/M80 Series Connection and Setup Manual
4 General Specifications
Input/output circuit
HA1A
HA2A
Signal
input
HA1B
HA2B
Power
output
When using the synchronous feed encoder and the manual pulse generator at the same time, connect
the manual pulse generator to the operation panel I/O unit or use a distribution cable made by the
machine tool builder.
(16) SKIP (SKIP input 8 points)
10
20
1
COM GND
2
I
SKIP IN1
3
I
SKIP IN3
4
NC
5
COM GND
6
NC
7
I
SKIP IN5
8
I
SKIP IN7
9
NC
10
NC
- Connect connector case with FG pattern.
<Cable side connector type>
Plug : 10120-3000PE
Shell : 10320-52F0-008
Recommended manufacturer : 3M
(Note)
+5V
Connector
pin No.
R
R
8
7
C
+5V
0V
R
R
18
17
C
0V
+5V
10
+5V
20
0V
1
0V
11
0V
1
11
11
COM GND
12
I
SKIP IN2
13
I
SKIP IN4
14
NC
15
COM GND
16
NC
17
I
SKIP IN6
18
I
SKIP IN8
19
NC
20
NC
When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws
too tightly otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05N·m)
Control
circuit
31
IB-1501269-F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M800s series

Table of Contents